Parameters
Name
The name of the ModFrame component. This name will be visible below the ModFrame component in the ModFrame Client configuration panel.
The name of a ModFrame component must be unique within the container it resides in. |
Ident definition
This is the ident definition of the identifiers to expose.
Refresh options
With this property it is possible to decide when to refresh the exposed identifiers. The alternatives are:
- Never. The exposed identifiers will never be updated.
- Time advance. The exposed identifiers are updated every time step.
- Externally trigged. The exposed identifiers are updated on demand based on a trigger signal.
Search level
This property is used to decide how to restrict the boundary for what material to expose. The alternatives are:
- Process unit. The identifiers of material in a specific process unit are exposed.
- Tracker process unit. The identifiers of material in a specific tracker process unit are exposed.
Process unit
This property defines the process unit for which to expose material identifiers when the Search level property is set to Process unit.
Tracker Process Unit
This property defines the tracker process unit for which to expose material identifiers when the Search level property is set to Process unit.
Report result
When true, lookup results are written to the log.
Expose only made material
When this property are true, only the material that is made will be exposed. Material in the appending state will not be exposed.
Unique identifier values
When this property is true, duplicates will only be listed once.