Signals
The signals tab enables miscellaneous internal TPU data to be exposed on ports.
Total AMO
This parameter makes the total amount in the TPU available as a port value. The port is named STS Total Amount.
Active carrier
This parameter makes the name of the active carrier in the TPU available as a port value. The port is named STS Active carrier.
Total AMO out
This parameter makes the total amount led out of the TPU available as a port value. The port is named STS Total Amount Out.
Contained tracking material id’s
Displays all the tracking material id's contained in this TPU in a vector port. The port is named STS Contained TraMaIDs.
Total Material Count
This parameter makes the total count of tracking materials in the TPU available as a port value. The port is named STS Total Material count.
Process Unit ID
This parameter makes the process unit ID of the tracker process unit available as a port value. The port is named STS ProcessUnitID.
Tracker Process Unit ID
This parameter makes the tracker process unit ID of the tracker process unit available as a port value. The port is named STS TrackerProcessUnitID.